1. Dilute the sample
OK
Automatic method Gravimetric dilutors
Automatic dilution with DiluFlow
Automatically dilute the sample with the appropriate mass of diluent.
Chronometer 1:05
Fast: 225 mL in 8 s
Dilution accuracy: > 99% (in Standard or Accurate mode under optimal conditions)
Reproducible
Secure
Automatic traceability
Our gravimetric dilutors
Gravimetric dilutors
Our gravimetric dilutors
Gravimetric dilutors
No
Manual method Manual dilution
Weight and dilute a the sample
Weigh the sample and manually add the diluent.
Chronometer 4:00
Long and tedious
Lack of precision
Not reproducible
Lack of security
Manual traceability
2. Blend the sample
OK
Manual method Laboratory blenders
Blending the sample with BagMixer
Chronometer 2:00
Time saving on cleaning
Filtration and blending
No cross-contamination
Optimal bacterial extraction
Our laboratory blenders
Lab blenders
Our laboratory blenders
Lab blenders
No
Manual method Sample grinding
Sample grinding in a blender
Chronometer 3:00
Time consuming cleaning
No filtration
Risk of cross-contamination
Undesirable cell lysis
3. Collect the filtrate
OK
Automatic method Filter bags for blenders
Collect the filtrate in an interscience filter bag
Diluted and blended sample particles
Diluted and blended sample particles in the bag
Microorganisms to be analyzed
Microorganisms to be analyzed
Filter
Instant filtration
Easy pipetting
Our filter bags for blenders
Blender bags with filter
Diluted and blended sample particles
Diluted and blended sample particles in the bag
Microorganisms to be analyzed
Microorganisms to be analyzed
Filter
Our filter bags for blenders
Blender bags with filter
No
Manual method Bag without filter
Collect the filtrate in a bag without filter
No filtration
Blocked pipette
4. Dilute and plate the sample
OK
Automatic method Automatic platers
Automatic plating with easySpiral
Chronometer 0:25
From 100 to 1x107 CFU/mL on 1 Petri dish
Up to 75% savings in consumables
75% savings on consumables automatic method
Automatic traceability to automatic colony counters with dataLink
Our automatic platers
Automatic platers
Our automatic platers
Automatic platers
No
Manual method Manual plating
Manual serial dilutions
Chronometer 3:40
Repetitive action method: 4 dilutions + 4 successive platings
Lots of consumables
Consumables used with the manual method
Manual traceability
5. Counting the colonies
OK
Automatic method Automatic colony counters
Simplified counting with filter bag - Correlation for automatic counting
Chronometer 2:00
Counting is simplified with the use of a filter bag
Standardized and reproducible results (Study conducted on Bacillus cereus , Escherichia coli and Lactobacillus casei .)
Results exported and archived automatically
Traceability export data - Connection SIL/LIMS
Connexion LIMS
Traceability export data - 21 CFR Part 11
Audit trail
Bar-code
Bar-code
Import data traceability - DataLink
dataLink
Traceability export data - PDF
PDF
Traceability export data - Saving and archiving sessions
Backup and archive sessions
Traceability export data - JPG
JPG, PNG, BMP
Traceability export data - CSV
CSV
Traceability export data
ExcelTM OpenOfficeTM
Our Automatic colony counters
Colony counters
Our Automatic colony counters
Colony counters
No
Manual method Manual counting
Counting is difficult with a bag without filter - Correlation for manual counting
Chronometer 6:00
Difficult counting with the use of a bag without a filter
Variable and uncertain results
Results entered manually: error-prone and time-consuming